Full Range of Model Specifications.

Wall-Mounted Ductless Split Systems come in a range of sizes and capacities. Click on the model number for detailed installation information. Take a look.

We’ve also included definitions of some common air conditioning terms. Contact us if you would like us to add one that we’ve missed.

Moisture Removal
Measured in pints per hour, this rates the air conditioner’s dehumidifying capability.
1.69–10.1 pints/24 hours
Air Circulation (CFM)
The amount of air that moves past a stationary point in one minute. Measured in cubic feet per minute.
217–700ft3/min
Cooling Capacity
Air conditioner capacities are rated in Btu per hour. This is the measurement used to match your cooling or heating needs with an air conditioner. Btu stands for British Thermal Unit, which is the amount of heat needed to raise the temperature of one pound of water by one degree Fahrenheit.
8500–33000 Btu/hr
Heating Capacity
Air conditioner capacities are rated in Btu per hour. This is the measurement used to match your cooling or heating needs with an air conditioner. Btu stands for British Thermal Unit, which is the amount of heat needed to raise the temperature of one pound of water by one degree Fahrenheit.
6700–27600 Btu/hr
EER
The Energy Efficiency Ratio measures how efficiently an air conditioner will operate when the outdoor temperature is 95°. The ratio is calculated by dividing the cooling capacity (Btu/h) by the power needed to run the unit (watts). The higher the EER, the more efficient the air conditioner and the less costly it is to operate.
8.5–14.0

Individual Specifications

Click model number for detailed specifications.

Wall-Mounted (Cool Only)

Model Cooling Capacity
(Btu/hr)
Heating Capacity
(Btu/hr)
SEER EER Energy Star Qualified
M09CH 9000 n/a 22.0 14.0 Yes

This system includes one MW09C1H indoor component and one MR09C1H outdoor component.

M09CH-MW09C1H - Indoor Component

  • Unit Dimensions

    Height
    10 7/8"
    Width
    33 1/4"
    Depth
    7 1/8"
    Max. Line Length
    66'
    Max. Height Difference
    33'

Detailed Electrical Information

Voltage
115
Max. Total Draw Fuse/Breaker
25
Power Cord Length
Hard Wired
Air Circulation
329 cubic feet per minute
Est. Yearly Operating Costs
n/a
Moisture Removal
1.69 pints/hour
Net Weight
24 lbs
Operating Temperatures (Cooling, °F)
60-115
Operating Temperatures (Heating, °F)
n/a
Performance Certifications
AHRI, ETL, cETL
Shipping Weight
32 lbs
Suggested Retail Price
Please contact your local retailer or distributor for pricing

M09CH-MR09C1H - Outdoor Component

  • Unit Dimensions

    Height
    12 5/8"
    Width
    33 3/8"
    Depth
    21 1/4"
Net Weight
80 lbs
Shipping Weight
90 lbs
Performance Certifications
AHRI, ETL, cETL
M12CH 12000 n/a 20.0 13.5 Yes

This system includes one MW12C1H indoor component and one MW12C1H outdoor component.

M12CH-MW12C1H - Indoor Component

  • Unit Dimensions

    Height
    10 7/8"
    Width
    33 1/4"
    Depth
    7 1/8"
    Max. Line Length
    66'
    Max. Height Difference
    33'

Detailed Electrical Information

Voltage
115
Max. Total Draw Fuse/Breaker
25
Power Cord Length
Hard Wired
Air Circulation
300 cubic feet per minute
Est. Yearly Operating Costs
n/a
Moisture Removal
2.53 pints/hour
Net Weight
24 lbs
Operating Temperatures (Cooling, °F)
60-115
Operating Temperatures (Heating, °F)
n/a
Performance Certifications
AHRI, ETL, cETL
Shipping Weight
26 lbs
Suggested Retail Price
Please contact your local retailer or distributor for pricing

M12CH-MR12C1H - Outdoor Component

  • Unit Dimensions

    Height
    12 5/8"
    Width
    33 3/8"
    Depth
    21 1/4"
Net Weight
90 lbs
Shipping Weight
97 lbs
Performance Certifications
AHRI, ETL, cETL
M24CG 24000 n/a 17.5 10.0

This system includes one MW24C3G indoor component and one MR24C3G outdoor component.

M24CG-MW24C3G - Indoor Component

  • Unit Dimensions

    Height
    12 5/8"
    Width
    39 1/4"
    Depth
    9"
    Max. Line Length
    98'
    Max. Height Difference
    66'

Detailed Electrical Information

Voltage
230/208
Max. Total Draw Fuse/Breaker
20
Power Cord Length
Hard Wired
Air Circulation
659 cubic feet per minute
Est. Yearly Operating Costs
n/a
Moisture Removal
6.3 pints/hour
Net Weight
31 lbs
Operating Temperatures (Cooling, °F)
60-115
Operating Temperatures (Heating, °F)
n/a
Performance Certifications
AHRI, ETL, cETL
Shipping Weight
40 lbs
Suggested Retail Price
Please contact your local retailer or distributor for pricing

M24CG-MR24C3G - Outdoor Component

  • Unit Dimensions

    Height
    24 7/16"
    Width
    31 1/8"
    Depth
    11 3/4"
Net Weight
88 lbs
Shipping Weight
97 lbs
Performance Certifications
AHRI, ETL, cETL
M18CF 18000 n/a 19.0 10.4

This system includes one MW18C3F indoor component and one MR18C3F outdoor component.

M18CF-MW18C3F - Indoor Component

  • Unit Dimensions

    Height
    10 7/8"
    Width
    31 1/8"
    Depth
    8 1/2"
    Max. Line Length
    66'
    Max. Height Difference
    49'

Detailed Electrical Information

Voltage
230/208
Max. Total Draw Fuse/Breaker
20
Power Cord Length
Hard Wired
Air Circulation
415 cubic feet per minute
Est. Yearly Operating Costs
n/a
Moisture Removal
5.9 pints/hour
Net Weight
21 lbs
Operating Temperatures (Cooling, °F)
60-115
Operating Temperatures (Heating, °F)
n/a
Performance Certifications
AHRI, ETL, cETL
Shipping Weight
26 lbs
Suggested Retail Price
Please contact your local retailer or distributor for pricing

M18CF-MR18C3F - Outdoor Component

  • Unit Dimensions

    Height
    22 3/4"
    Width
    31 1/8"
    Depth
    12 3/8"
Net Weight
88 lbs
Shipping Weight
97 lbs
Performance Certifications
AHRI, ETL, cETL
M30CG 30700 n/a 16.5 9.5

This system includes one MW30C3G indoor component and one MR30C3G outdoor component.

M30CG-MW30C3G - Indoor Component

  • Unit Dimensions

    Height
    12 5/8"
    Width
    39 1/4"
    Depth
    9"
    Max. Line Length
    164'
    Max. Height Difference
    98'

Detailed Electrical Information

Voltage
230/208
Max. Total Draw Fuse/Breaker
30
Power Cord Length
Hard Wired
Air Circulation
660 cubic feet per minute
Est. Yearly Operating Costs
n/a
Moisture Removal
9.7 pints/hour
Net Weight
31 lbs
Operating Temperatures (Cooling, °F)
60-115
Operating Temperatures (Heating, °F)
n/a
Performance Certifications
AHRI, ETL, cETL
Shipping Weight
40 lbs
Suggested Retail Price
Please contact your local retailer or distributor for pricing

M30CG-MR30C3G - Outdoor Component

  • Unit Dimensions

    Height
    35 5/8"
    Width
    32 3/4"
    Depth
    13"
Net Weight
135 lbs
Shipping Weight
150 lbs
Performance Certifications
AHRI, ETL, cETL
M36CG 33000 n/a 15.5 8.5

This system includes one MW36C3G indoor component and one MR36C3G outdoor component.

M36CG-MW36C3G - Indoor Component

  • Unit Dimensions

    Height
    12 5/8"
    Width
    39 1/4"
    Depth
    9"
    Max. Line Length
    164'
    Max. Height Difference
    98'

Detailed Electrical Information

Voltage
230/208
Max. Total Draw Fuse/Breaker
30
Power Cord Length
Hard Wired
Air Circulation
700 cubic feet per minute
Est. Yearly Operating Costs
n/a
Moisture Removal
10.1 pints/hour
Net Weight
31 lbs
Operating Temperatures (Cooling, °F)
60-115
Operating Temperatures (Heating, °F)
n/a
Performance Certifications
AHRI, ETL, cETL
Shipping Weight
40 lbs
Suggested Retail Price
Please contact your local retailer or distributor for pricing

M36CG-MR36C3G - Outdoor Component

  • Unit Dimensions

    Height
    35 3/8"
    Width
    32 3/4"
    Depth
    13"
Net Weight
135 lbs
Shipping Weight
150 lbs
Performance Certifications
AHRI, ETL, cETL

Wall-Mounted Single-Zone Heat Pumps

Model Cooling Capacity
(Btu/hr)
Heating Capacity
(Btu/hr)
SEER EER Energy Star Qualified
M09YH 8500 10000 21.0 12.5 Yes

This system includes one MW09Y3H indoor component and one MR09Y3H outdoor component.

M09YH-MW09Y3H - Indoor Component

  • Unit Dimensions

    Height
    11 1/32"
    Width
    31 3/32"
    Depth
    7 25/32"
    Max. Line Length
     66'
    Max. Height Difference
     49'

Detailed Electrical Information

Voltage
230/208
Max. Total Draw Fuse/Breaker
15
Power Cord Length
Hard Wired
Air Circulation
447 cubic feet per minute
Est. Yearly Operating Costs
$54
Moisture Removal
2.7 pints/hour
Net Weight
lbs
Operating Temperatures (Cooling, °F)
60-115
Operating Temperatures (Heating, °F)
5-75
Performance Certifications
AHRI, ETL, cETL
Shipping Weight
21 lbs
Suggested Retail Price
Please contact your local retailer or distributor for pricing

M09YH-MR09Y3H - Outdoor Component

  • Unit Dimensions

    Height
    21 1/4"
    Width
    25 31/32"
    Depth
    11 13/32"
Net Weight
55 lbs
Shipping Weight
62 lbs
Performance Certifications
AHRI, ETL, cETL
M12YH 11500 14000 21.0 12.5 Yes

This system includes one MW12Y3H indoor component and one MR12Y3H outdoor component.

M12YH-MW12Y3H - Indoor Component

  • Unit Dimensions

    Height
    11 1/32"
    Width
    31 3/32"
    Depth
    7 25/32"
    Max. Line Length
    66'
    Max. Height Difference
    49'

Detailed Electrical Information

Voltage
230/208
Max. Total Draw Fuse/Breaker
15
Power Cord Length
Hard Wired
Air Circulation
447 cubic feet per minute
Est. Yearly Operating Costs
$73
Moisture Removal
3.8 pints/hour
Net Weight
lbs
Operating Temperatures (Cooling, °F)
60-115
Operating Temperatures (Heating, °F)
5-75
Performance Certifications
AHRI, ETL, cETL
Shipping Weight
21 lbs
Suggested Retail Price
Please contact your local retailer or distributor for pricing

M12YH-MR12Y3H - Outdoor Component

  • Unit Dimensions

    Height
    21 1/4"
    Width
    25 31/32"
    Depth
    11 13/32"
Net Weight
68 lbs
Shipping Weight
75 lbs
Performance Certifications
AHRI, ETL, cETL
M18YH 18000 21600 19.2 13.0 Yes

This system includes one MW18Y3H indoor component and one MR18Y3H outdoor component.

M18YH-MW18Y3H - Indoor Component

  • Unit Dimensions

    Height
    12 5/8"
    Width
    39 1/4"
    Depth
    9"
    Max. Line Length
    164'
    Max. Height Difference
    98'

Detailed Electrical Information

Voltage
230/208
Max. Total Draw Fuse/Breaker
20
Power Cord Length
Hard Wired
Air Circulation
540 cubic feet per minute
Est. Yearly Operating Costs
$111
Moisture Removal
5.9 pints/hour
Net Weight
31 lbs
Operating Temperatures (Cooling, °F)
60-115
Operating Temperatures (Heating, °F)
5-75
Performance Certifications
AHRI, ETL, cETL
Shipping Weight
40 lbs
Suggested Retail Price
Please contact your local retailer or distributor for pricing

M18YH-MR18Y3H - Outdoor Component

  • Unit Dimensions

    Height
    35 3/8"
    Width
    32 3/4"
    Depth
    13"
Net Weight
135 lbs
Shipping Weight
150 lbs
Performance Certifications
AHRI, ETL, cETL
M24YH 22000 27600 18.0 12.5 Yes

This system includes one MW24Y3H indoor component and one MR24Y3H outdoor component.

M24YH-MW24Y3H - Indoor Component

  • Unit Dimensions

    Height
    12 5/8"
    Width
    39 1/4"
    Depth
    9"
    Max. Line Length
    164'
    Max. Height Difference
    98'

Detailed Electrical Information

Voltage
230/208
Max. Total Draw Fuse/Breaker
30
Power Cord Length
Hard Wired
Air Circulation
660 cubic feet per minute
Est. Yearly Operating Costs
$141
Moisture Removal
6.3 pints/hour
Net Weight
31 lbs
Operating Temperatures (Cooling, °F)
0 - 115
Operating Temperatures (Heating, °F)
0-75
Performance Certifications
AHRI, ETL, cETL
Shipping Weight
40 lbs
Suggested Retail Price
Please contact your local retailer or distributor for pricing

M24YH-MR24Y3H - Outdoor Component

  • Unit Dimensions

    Height
    35 5/8"
    Width
    32 3/4"
    Depth
    13"
Net Weight
135 lbs
Shipping Weight
150 lbs
Performance Certifications
AHRI, ETL, cETL

Wall-Mounted Multi-Zone Heat Pumps

Model Cooling Capacity
(Btu/hr)
Heating Capacity
(Btu/hr)
SEER EER Energy Star Qualified
M36QYF 8800 EA 38000 15.0 8.8

This system includes four MW09Y3FM indoor components and one MR36TQY3F outdoor component.

M36QYF-MW09Y3FM - Indoor Component

  • Unit Dimensions

    Height
    10 7/8"
    Width
    31 1/8"
    Depth
    8 1/2"
    Max. Line Length
    unit 82 total 230
    Max. Height Difference
    49'

Detailed Electrical Information

Voltage
230/208
Max. Total Draw Fuse/Breaker
30
Power Cord Length
Hard Wired
Air Circulation
295 cubic feet per minute
Est. Yearly Operating Costs
$312
Moisture Removal
2.9 pints/hour
Net Weight
21 lbs
Operating Temperatures (Cooling, °F)
60-115
Operating Temperatures (Heating, °F)
14-75
Performance Certifications
AHRI, ETL, cETL
Shipping Weight
26 lbs
Suggested Retail Price
Please contact your local retailer or distributor for pricing

M36QYF-MR36TQY3F - Outdoor Component

  • Unit Dimensions

    Height
    32 5/8"
    Width
    35 3/8"
    Depth
    13"
Net Weight
149 lbs
Shipping Weight
167 lbs
Performance Certifications
AHRI, ETL, cETL
M36TYF1 9100 EA + 17000 38000 15.0 8.8

This system includes two MW09Y3FM indoor components, one MW18Y3FM indoor component, and one MR36TQY3F outdoor component.

M36TYF1-MW09Y3FM - Indoor Component

  • Unit Dimensions

    Height
    10 7/8"
    Width
    31 1/8"
    Depth
    8 1/2"
    Max. Line Length
    unit 82 total 230
    Max. Height Difference
    49'

Detailed Electrical Information

Voltage
230/208
Max. Total Draw Fuse/Breaker
30
Power Cord Length
Hard Wired
Air Circulation
295 cubic feet per minute
Est. Yearly Operating Costs
$320
Moisture Removal
2.9 pints/hour
Net Weight
21 lbs
Operating Temperatures (Cooling, °F)
60-115
Operating Temperatures (Heating, °F)
14-75
Performance Certifications
AHRI, ETL, cETL
Shipping Weight
26 lbs
Suggested Retail Price
Please contact your local retailer or distributor for pricing

M36TYF1-MW18Y3FM - Indoor Component

  • Unit Dimensions

    Height
    10 7/8"
    Width
    31 1/8"
    Depth
    8 1/2"
    Max. Line Length
    unit 82 total 230
    Max. Height Difference
    49'

Detailed Electrical Information

Voltage
230/208
Max. Total Draw Fuse/Breaker
Power Cord Length
Hard Wired
Air Circulation
415 cubic feet per minute
Est. Yearly Operating Costs
n/a
Moisture Removal
5.7 pints/hour
Net Weight
21 lbs
Operating Temperatures (Cooling, °F)
60-115
Operating Temperatures (Heating, °F)
14-75
Performance Certifications
AHRI, ETL, cETL
Shipping Weight
26 lbs
Suggested Retail Price
Please contact your local retailer or distributor for pricing

M36TYF1-MR36TQY3F - Outdoor Component

  • Unit Dimensions

    Height
    32 5/8"
    Width
    35 3/8"
    Depth
    13"
Net Weight
149 lbs
Shipping Weight
167 lbs
Performance Certifications
AHRI, ETL, cETL
M27TYF 9200 EA 33600 15.0 10.0

This system includes three MW09Y3FM indoor components and one MR36TQY3F outdoor component.

M27TYF-MW09Y3FM - Indoor Component

  • Unit Dimensions

    Height
    10 7/8"
    Width
    31 1/8"
    Depth
    8 1/2"
    Max. Line Length
    unit 82 total 230
    Max. Height Difference
    49'

Detailed Electrical Information

Voltage
230/208
Max. Total Draw Fuse/Breaker
30
Power Cord Length
Hard Wired
Air Circulation
295 cubic feet per minute
Est. Yearly Operating Costs
$216
Moisture Removal
2.9 pints/hour
Net Weight
21 lbs
Operating Temperatures (Cooling, °F)
60-115
Operating Temperatures (Heating, °F)
14-75
Performance Certifications
AHRI, ETL, cETL
Shipping Weight
26 lbs
Suggested Retail Price
Please contact your local retailer or distributor for pricing

M27TYF-MR36TQY3F - Outdoor Component

  • Unit Dimensions

    Height
    32 5/8"
    Width
    35 3/8"
    Depth
    13"
Net Weight
149 lbs
Shipping Weight
167 lbs
Performance Certifications
AHRI, ETL, cETL
M30TYF 9300 EA + 11800 36000 15.0 9.2

This system includes two MW09Y3FM indoor components, one MW12Y3FM indoor component, and one MR36TQY3F outdoor component.

M30TYF-MW09Y3FM - Indoor Component

  • Unit Dimensions

    Height
    10 7/8"
    Width
    31 1/8"
    Depth
    8 1/2"
    Max. Line Length
    unit 82 total 230
    Max. Height Difference
    49'

Detailed Electrical Information

Voltage
230/208
Max. Total Draw Fuse/Breaker
30
Power Cord Length
Hard Wired
Air Circulation
295 cubic feet per minute
Est. Yearly Operating Costs
$254
Moisture Removal
2.9 pints/hour
Net Weight
21 lbs
Operating Temperatures (Cooling, °F)
60-115
Operating Temperatures (Heating, °F)
14-75
Performance Certifications
AHRI, ETL, cETL
Shipping Weight
26 lbs
Suggested Retail Price
Please contact your local retailer or distributor for pricing

M30TYF-MW12Y3FM - Indoor Component

  • Unit Dimensions

    Height
    10 7/8"
    Width
    31 1/8"
    Depth
    8 1/2"
    Max. Line Length
    unit 82 total 230
    Max. Height Difference
    49'

Detailed Electrical Information

Voltage
230/208
Max. Total Draw Fuse/Breaker
30
Power Cord Length
Hard Wired
Air Circulation
355 cubic feet per minute
Est. Yearly Operating Costs
n/a
Moisture Removal
3.7 pints/hour
Net Weight
21 lbs
Operating Temperatures (Cooling, °F)
60-115
Operating Temperatures (Heating, °F)
14-75
Performance Certifications
AHRI, ETL, cETL
Shipping Weight
26 lbs
Suggested Retail Price
Please contact your local retailer or distributor for pricing

M30TYF-MR36TQY3F - Outdoor Component

  • Unit Dimensions

    Height
    32 5/8"
    Width
    35 3/8"
    Depth
    13"
Net Weight
149 lbs
Shipping Weight
167 lbs
Performance Certifications
AHRI, ETL, cETL
M33TYF 9400 +
11800 EA
25600 15.0 8.8

This system includes one MW09Y3FM indoor component, two MW12Y3FM indoor components, and one MR36TQY3F outdoor component.

M33TYF-MW09Y3FM - Indoor Component

  • Unit Dimensions

    Height
    10 7/8"
    Width
    31 1/8"
    Depth
    8 1/2"
    Max. Line Length
    unit 82 total 230
    Max. Height Difference
    49'

Detailed Electrical Information

Voltage
230/208
Max. Total Draw Fuse/Breaker
30
Power Cord Length
Hard Wired
Air Circulation
295 cubic feet per minute
Est. Yearly Operating Costs
$296
Moisture Removal
2.9 pints/hour
Net Weight
21 lbs
Operating Temperatures (Cooling, °F)
60-115
Operating Temperatures (Heating, °F)
14-75
Performance Certifications
AHRI, ETL, cETL
Shipping Weight
26 lbs
Suggested Retail Price
Please contact your local retailer or distributor for pricing

M33TYF-MW12Y3FM - Indoor Component

  • Unit Dimensions

    Height
    10 7/8"
    Width
    31 1/8"
    Depth
    8 1/2"
    Max. Line Length
    unit 82 total 230
    Max. Height Difference
    49'

Detailed Electrical Information

Voltage
230/208
Max. Total Draw Fuse/Breaker
30
Power Cord Length
Hard Wired
Air Circulation
355 cubic feet per minute
Est. Yearly Operating Costs
n/a
Moisture Removal
3.7 pints/hour
Net Weight
21 lbs
Operating Temperatures (Cooling, °F)
60-115
Operating Temperatures (Heating, °F)
14-75
Performance Certifications
AHRI, ETL, cETL
Shipping Weight
26 lbs
Suggested Retail Price
Please contact your local retailer or distributor for pricing

M33TYF-MR36TQY3F - Outdoor Component

  • Unit Dimensions

    Height
    32 5/8"
    Width
    35 3/8"
    Depth
    13"
Net Weight
149 lbs
Shipping Weight
167 lbs
Performance Certifications
AHRI, ETL, cETL
M36TYF2 11700 EA 38100 15.0 8.8

This system includes three MW12Y3FM indoor components and one MR36TQY3F outdoor component.

M36TYF2-MW12Y3FM - Indoor Component

  • Unit Dimensions

    Height
    10 7/8"
    Width
    31 1/8"
    Depth
    8 1/2"
    Max. Line Length
    unit 82 total 230
    Max. Height Difference
    49'

Detailed Electrical Information

Voltage
230/208
Max. Total Draw Fuse/Breaker
30
Power Cord Length
Hard Wired
Air Circulation
355 cubic feet per minute
Est. Yearly Operating Costs
$318
Moisture Removal
3.7 pints/hour
Net Weight
21 lbs
Operating Temperatures (Cooling, °F)
60-115
Operating Temperatures (Heating, °F)
14-75
Performance Certifications
AHRI, ETL, cETL
Shipping Weight
26 lbs
Suggested Retail Price
Please contact your local retailer or distributor for pricing

M36TYF2-MR36TQY3F - Outdoor Component

  • Unit Dimensions

    Height
    32 5/8"
    Width
    35 3/8"
    Depth
    13"
Net Weight
149 lbs
Shipping Weight
167 lbs
Performance Certifications
AHRI, ETL, cETL
M18DYF 9500 EA 22000 16.5 12.2

This system includes two MW09Y3FM indoor components and one MR24DY3FM outdoor component.

M18DYF- MW09Y3FM - Indoor Component

  • Unit Dimensions

    Height
    10 7/8"
    Width
    31 1/8"
    Depth
    8 1/2"
    Max. Line Length
    unit 82 total 98
    Max. Height Difference
    33'

Detailed Electrical Information

Voltage
230/208
Max. Total Draw Fuse/Breaker
20
Power Cord Length
Hard Wired
Air Circulation
295 cubic feet per minute
Est. Yearly Operating Costs
$128
Moisture Removal
2.9 pints/hour
Net Weight
21 lbs
Operating Temperatures (Cooling, °F)
60-115
Operating Temperatures (Heating, °F)
14-75
Performance Certifications
AHRI, ETL, cETL
Shipping Weight
26 lbs
Suggested Retail Price
Please contact your local retailer or distributor for pricing

M18DYF-MR24DY3FM - Outdoor Component

  • Unit Dimensions

    Height
    32 5/8"
    Width
    35 3/8"
    Depth
    13"
Net Weight
136 lbs
Shipping Weight
154 lbs
Performance Certifications
AHRI, ETL, cETL
M21DYF 9500 + 12000 25000 16.5 11.2

This system includes one MW09Y3FM indoor component, one MW12Y3FM indoor component, and one MR24DY3FM outdoor component.

M21DYF-MW12Y3FM - Indoor Component

  • Unit Dimensions

    Height
    10 7/8"
    Width
    31 1/8"
    Depth
    8 1/2"
    Max. Line Length
    unit 82 total 98
    Max. Height Difference
    33'

Detailed Electrical Information

Voltage
230/208
Max. Total Draw Fuse/Breaker
20
Power Cord Length
Hard Wired
Air Circulation
355 cubic feet per minute
Est. Yearly Operating Costs
$152
Moisture Removal
3.7 pints/hour
Net Weight
21 lbs
Operating Temperatures (Cooling, °F)
60-115
Operating Temperatures (Heating, °F)
14-75
Performance Certifications
AHRI, ETL, cETL
Shipping Weight
26 lbs
Suggested Retail Price
Please contact your local retailer or distributor for pricing

M21DYF-MR24DY3FM - Outdoor Component

  • Unit Dimensions

    Height
    32 5/8"
    Width
    35 3/8"
    Depth
    13"
Net Weight
136 lbs
Shipping Weight
154 lbs
Performance Certifications
AHRI, ETL, cETL
M24DYF 12000 EA 28000 16.5 10.4

This system includes two MW12Y3FM indoor components, and one MR24DY3FM outdoor component.

M24DYF-MW12Y3FM - Indoor Component

  • Unit Dimensions

    Height
    10 7/8"
    Width
    31 1/8"
    Depth
    8 1/2"
    Max. Line Length
    unit 82 total 98
    Max. Height Difference
    33'

Detailed Electrical Information

Voltage
230/208
Max. Total Draw Fuse/Breaker
20
Power Cord Length
Hard Wired
Air Circulation
355 cubic feet per minute
Est. Yearly Operating Costs
$184
Moisture Removal
3.7 pints/hour
Net Weight
21 lbs
Operating Temperatures (Cooling, °F)
0 - 115
Operating Temperatures (Heating, °F)
14-75
Performance Certifications
AHRI, ETL, cETL
Shipping Weight
26 lbs
Suggested Retail Price
Please contact your local retailer or distributor for pricing

M24DYF-MR24DY3FM - Outdoor Component

  • Unit Dimensions

    Height
    32 5/8"
    Width
    35 3/8"
    Depth
    13"
Net Weight
136 lbs
Shipping Weight
154 lbs
Performance Certifications
AHRI, ETL, cETL

Energy Guide Label